CBGA-LJN Counterbalance Valve – Sun Hydraulics CBGA Series, 3:1 Pilot Ratio, 240 L/min, T-17A Cavity
CBGA-LJN Counterbalance Valve — Sun Hydraulics CBGA Series
The CBGA-LJN is referenced in aftermarket listings as a counterbalance (load-holding) cartridge valve belonging to the Sun Hydraulics CBGA series. It is designed to control overrunning loads, prevent load drift, and provide hose-break protection in hydraulic circuits.
Confirmed CBGA Series Specifications (Reference)
The following data applies to the CBGA series as documented by Sun Hydraulics. The “LJN” suffix indicates specific configuration options (adjustment style, seal material, setting range) that may alter some parameters:
-
Function: 3:1 pilot ratio, standard capacity counterbalance valve
-
Cavity: T-17A (Series 3)
-
Capacity: 60 gpm (240 L/min)
-
Pilot ratio: 3:1
-
Maximum setting: 4000 psi (280 bar)
-
Maximum recommended load pressure at maximum setting: 3075 psi (215 bar)
-
Maximum valve leakage at reseat: 5 drops/min (0.3 cc/min)
-
Reseat: >85% of setting
-
Valve hex size: 1 1/4 in. (31.8 mm)
-
Installation torque: 150–160 lbf ft (203–217 Nm)
-
Model weight: approximately 1.60 lb (0.70 kg)
Critical Verification Required
The specific combination “LJN” as a suffix for CBGA is not documented in Sun Hydraulics’ official CBGA model pages or configuration tables reviewed. Standard Sun configuration codes use letter suffixes to denote functional setting range (e.g., H, I, A, B), seal material (N, V, E), and adjustment type (L for screw adjustment). While “L” and “N” appear in Sun’s coding system, “J” does not correspond to a documented functional setting range for the CBGA series in available official sources .
What This Means for Buyers
-
Do not assume the “LJN” suffix matches a standard Sun factory configuration. It may represent a custom or non-standard variant, an aftermarket designation, or a coding used by a specific distributor.
-
Verify the functional setting range (pressure range) and check valve cracking pressure (0.3 bar vs. 1.7 bar) against your application requirements.
-
If you require genuine Sun Hydraulics product, request written confirmation of the exact configuration and factory setting before ordering.
Operating Principles (CBGA Series)
Counterbalance valves with pilot assist control overrunning loads. The check valve allows free flow from port 2 (directional valve) to port 1 (load), while a direct-acting, pilot-assisted relief function controls flow from port 1 to port 2. Pilot pressure at port 3 reduces the effective relief setting at a rate determined by the pilot ratio .
Application Notes (Sun Official Guidance)
-
The valve setting should be at least 1.3 times the maximum load-induced pressure .
-
Backpressure at port 2 adds to the effective relief setting at a rate of (1 + pilot ratio) × backpressure .
-
Counterbalance valves are pressure-dependent devices; do not oversize them, as higher pressure drop improves system stiffness and stability .
-
It is strongly recommended to set the valve before installation; field adjustment after installation is difficult due to pilot assist interaction with the actuator .
Ordering Notes
-
Confirm whether the unit is genuine Sun Hydraulics or an aftermarket equivalent.
-
Request the functional setting range (e.g., 1000–4000 psi or 400–1500 psi) and check valve cracking pressure explicitly.
-
Ask for a dimensional drawing or configuration confirmation if “LJN” is critical to your application.