HydraForce PV72-33 Proportional Flow Control Valve – Normally Closed, Spool Type, 3500 psi, 15 gpm, VC12-3 Cavity
HydraForce PV72-33 — Normally Closed Electro-Proportional Flow Control Cartridge
The PV72-33 is a solenoid-operated, spool-type, normally closed proportional flow control valve. It provides regulated flow from port ③ to port ②, with input from port ① blocked. Regulated flow is proportional to the electrical current applied to the solenoid .
Critical Application Note: This valve is designed for use with a pressure compensator at a pressure differential not exceeding 175 psi (12 bar). Port ① is used only to pressure-balance the spool and should be plugged in the circuit . It is not a standalone pressure relief or flow control solution.
Confirmed Specifications
-
Function: Normally closed proportional flow control, spool type
-
Cavity: VC12-3
-
Pressure rating: 240 bar (3500 psi); proof 345 bar (5000 psi); burst 896 bar (13000 psi)
-
Flow rating: 0 to 57 L/min (0 to 15.0 gpm)
-
Maximum internal leakage: 0.38 L/min (0.1 gpm) at 100% current
-
Flow ranges (model option): A = 80.6 L/min (21.3 gpm) max; B = 58.7 L/min (15.5 gpm) max
-
Electrical (24V coil): Max control current 750 mA; threshold current 150 mA
-
Electrical (12V coil): Max control current 1500 mA; threshold current 300 mA
-
Dither PWM frequency: 100–250 Hz
-
Fluid: Mineral-based or synthetic with lubricating properties; viscosity 7.4–420 cSt
-
Seals: Buna N standard; fluorocarbon, polyurethane options
Features
Excellent linearity and hysteresis characteristics. Hardened spool and cage for long life. Voltage-interchangeable cartridges. Unitized, molded coil with standard waterproofing. Manual override option available (M or G code) .
Ordering Notes
The full model code follows the format PV72-33DE-H-J-L. Key selections include:
-
D (flow range): A or B
-
E (override): Blank, G, or M
-
H (body): 0 (no body), 8T, 10T, 12T, etc.
-
J (seals): N (Buna N), V (Fluorocarbon), P (Polyurethane)
-
L (coil): 0 (no coil), 12DG, 24DG, 12DL, 24DL, etc.
Confirm the complete model string on your quotation to avoid substitution .
Important Distinction
PV72-33 is not a pressure relief valve and not a standalone proportional pressure control valve. It is a flow control element requiring an external pressure compensator (such as HydraForce EC12-30 or EC12-40) to function as a complete flow regulator . Misapplication without a compensator will result in flow varying with load pressure.